Select Engineering, Inc. offers four standard product groups:
-
Cross-Hatch Style for pre-wired applications
- Metal Snap and Eyelet for two-piece construction
- One-Piece Conductive Carbon for x-ray translucent applications
- Two-Piece Conductive Carbon for x-ray translucent applications
All of our product line, whether standard or custom, are distinguished by exceptional electrical characteristics. DC offset, impedance and defibrillation recovery all consistently test out at fractions of the accepted industry limits set by the Association for the Advancement of Medical Instrumentation (AAMI).
In fact, DC offset, a key determinant of an electrode's reliability, routinely measures .5 millivolts, compared with the AAMI ceiling of 100. What's more, such high performance hasn't come at the expense of the environment. Having designed its own water treatment/recycling system — as well as the inherently cleaner silver-deposition process — Select Engineering, Inc. far exceeds every legal standard for discharge purity.
|
|
 |
|
|
|
|
|
Cross-Hatch StyleWith
a special cross-hatched post to simplify ultrasonic welding to the lead
wire, the S-7001/CF is ideal for medical diagnostic and monitoring equipment
and other applications in bio-instrumentation. The S-7001/CF also features
a 0.1 mil Ag/AgCl coating evenly distributed over a conductive molded
plastic substrate to facilitate a positive electrical contact with the
lead wire. A proprietary deposition process, completely designed and
engineered in-house, ensures an extremely uniform coating that will
not flake or peel under even strenuous use. The S-7001/CF is available
in an x-ray transparent version, the SRT-7001, with a .06 mil coating
thickness. Like all of Select Engineering, Inc's. standard and custom sensors, including
x-ray transparent models, the S-7001 also offers exceptional electrical
performance, routinely recording mere fractions of accepted industry
limits for DC offset, impedance and defibrillation recovery. For example,
although specific values vary with the type of conductive gel used,
the company's stringent "zero defect" QA program produces
DC offset readings consistently below 1 mv, with minimal sensor-to-sensor
variation, compared to an AAMI ceiling of 100.
One-Piece Conductive CarbonDesigned
to accept a snap-on lead wire, the S-2651 sensor features a molded plastic
substrate covered with a 0.1 mil Ag/AgCl coating that will not flake
or peel under even the most strenuous use. A unique, environmentally
responsible deposition process, designed and engineered in-house, ensures
extreme coating uniformity, as well as flawless adhesion. Select Engineering, Inc. offers
a full range of application-specific coating thicknesses. Like all of
Select's standard and custom sensors, including x-ray transparent models,
the S-2651 sensor also boasts exceptional electrical performance, with
DC offset, impedance and defibrillation recovery all measuring out at
fractions of AAMI limits. Although specific values vary with the type
of conductive gel used, DC offset — a key determinant of sensitivity
— consistently reads below 1 mv, compared with an industry limit
of 100.
|
Metal Snap & EyeletThese
superior quality Sensors which are used in Heart Monitoring and Bioinstrumentation
Electrodes feature a non flaking coating that is uniformly distributed
over the molded plastic substrate.
Part No. S-9001 as shown has a 0.1
mil Silver thickness. Other coating thicknesses are available. The S-9001
is used in a Two-Piece type Electrode and is electrically tested for
DC Offset, Impedance, and Defibrillation Recovery to meet AAMI Standards.
The S-9001 mates with the S-9000 metal top snap, available in nickel
brass and stainless steel, to form a Two-Piece Electrode assembly.
Two-Piece Conductive CarbonOur series of disposable
radio-translucent electrode sensors are effectively invisible to
x-rays. Engineered to allow radiologic examinations without troublesome
electrode removal and replacement, Select Engineering, Inc's. SRT-type sensors minimize
the time medical patients must spend disconnected from ECG and other
vital monitoring equipment.
SRT x-ray translucent sensors are available
in both one- and two-piece designs, of either uncoated carbon fiber
or a silver/silver chloride coating over a conductive plastic substrate. Select Engineering, Inc's. popular SRT-7001/CF/40, for example, is a one-piece conductive
carbon sensor for prewired applications, while the SRT-3601 features
a 0.06 mil Ag/AgCl coating and mates with the SRT-2001/CF/40 carbon
top snap to form a two-piece assembly. A unique, environmentally responsible
deposition process, developed and engineered in-house, ensures that
Select's extremely uniform coatings will not flake or peel even in rigorous
use.
Like all of Select Engineering, Inc's. high-performance products, SRT sensors also
boast superior electrical characteristics. Under the company's stringent
programs of inspection and testing, Select's radio translucent sensors
consistently record mere fractions of industry-accepted AAMI limits
for DC offset, impedance and defibrillation recovery.
|
|
|
|
|
|